{"id":1015,"date":"2014-02-07T10:03:33","date_gmt":"2014-02-07T10:03:33","guid":{"rendered":"https:\/\/www.serengeo.com\/?page_id=1015"},"modified":"2021-05-11T14:02:59","modified_gmt":"2021-05-11T13:02:59","slug":"progettazione-di-impianti-geotermici","status":"publish","type":"page","link":"https:\/\/www.serengeo.com\/it\/geotermia\/progettazione-di-impianti-geotermici\/","title":{"rendered":"Progettazione di impianti geotermici"},"content":{"rendered":"\r\n<h1 class=\"wp-block-heading\">Progettazione di impianti geotermici<\/h1>\r\n\r\n\r\n\r\n<div class=\"wp-block-image\">\r\n<figure class=\"alignright is-resized\"><img decoding=\"async\" class=\"alignnone wp-image-2481 lazyload\" data-src=\"\/\/www.serengeo.com\/wp-content\/uploads\/2015\/05\/Sezione_particolari_pozzi-476x1024.png\" alt=\"\" width=\"197\" height=\"424\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 197px; --smush-placeholder-aspect-ratio: 197\/424;\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n\r\n<p align=\"justify\">Per dimensionare correttamente un grande impianto di climatizzazione e riscaldamento geotermico \u00e8 necessario analizzare le interazioni tra i vari geoscambiatori, per garantire il funzionamento del sistema\u00a0nel tempo.<br \/>Il servizio di progettazione di grandi impianti geotermici soddisfa tutti i casi in cui\u00a0 gli approcci e le metodologie standard non possono essere applicati. E&#8217; basato sulla progettazione integrata dell&#8217;impianto termico e di quello geotermico, sull&#8217;assistenza in fase di realizzazione e sul supporto nella gestione dell&#8217;impianto.<br \/>SERENGEO \u00e8 in grado di progettare complessi sistemi geotermici per il riscaldamento e la climatizzazione, grazie a:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>l&#8217;utilizzo esperto della geostatistica per la mappatura termica del sottosuolo;<\/li>\r\n<li>l&#8217;adozione di tecniche di progettazione avanzate;<\/li>\r\n<li>l&#8217;uso della modellazione numerica.<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><strong>Destinatari del servizio<\/strong><\/h2>\r\n\r\n\r\n\r\n<p>Il servizio \u00e8 rivolto alle\u00a0 <i>pubbliche amministrazione, imprese e i soggetti interessati al settore geotermico<\/i>, come i produttori di pompe di calore, le imprese di costruzione, i perforatori e i progettisti termotecnici.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\"><strong>Lavori svolti\u00a0e collaborazioni<\/strong><\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li><a href=\"\/\/www.serengeo.com\/it\/geotermia\/progettazione-di-impianti-geotermici\/studio-di-fattibilita-per-soluzioni-geotermiche-per-un-birrificio-artigianale\/\" target=\"_blank\" rel=\"noopener noreferrer\">2016. Studio di fattibilit\u00e0 per soluzioni geotermiche per un birrificio artigianale<\/a><\/li>\r\n<li><a href=\"\/\/www.serengeo.com\/it\/geotermia-produzione-di-energia-geotermoelettrica\/progettazione-di-impianti-geotermici\/mercato-ortofrutticolo-milano\/\" target=\"_blank\" rel=\"noopener noreferrer\">2015. Studio preliminare di un sistema\u00a0geotermico open loop per la riqualificazione di un mercato ortofrutticolo<\/a><\/li>\r\n<li><a title=\"Fattibilit\u00e0- casa e serra\" href=\"\/\/www.serengeo.com\/it\/geotermia\/progettazione-di-impianti-geotermici\/geotermia-produzione-di-energia-geotermoelettricaprogettazione-di-impianti-geotermicifattibilita-casa-e-serra\/\" target=\"_blank\" rel=\"noopener noreferrer\">2013. Studio di fattibilit\u00e0 per un&#8217;applicazione a pompa geotermica per una casa+ serra<\/a><\/li>\r\n<li><a title=\"Fattibilit\u00e0-Nuovo Pignone\" href=\"\/\/www.serengeo.com\/it\/geotermia\/progettazione-di-impianti-geotermici\/geotermia-produzione-di-energia-geotermoelettricaprogettazione-di-impianti-geotermicifattibilita-nuovo-pignone\/\" target=\"_blank\" rel=\"noopener noreferrer\">2012. Studio di fattibilit\u00e0 per Nuovo Pignone (General Electric) per la produzione termica associata all&#8217;uso di una pompa di calore a CO2<\/a><\/li>\r\n<li>2012 &#8211; 2014. Partecipazione al Progetto Europeo <a href=\"http:\/\/energia.regione.emilia-romagna.it\/entra-in-regione\/politiche-europee\/progetti-europei-1\/legend-2013-low-enthalpy-geothermal-energy-demonstration-cases-in-adriatic-area\">Legend<\/a><\/li>\r\n<li>2010 &#8211; 2012. Partecipazione al Progetto Europeo Geopower (<a href=\"http:\/\/www.geopower-i4c.eu\/\" target=\"_blank\" rel=\"noopener noreferrer\">http:\/\/www.geopower-i4c.eu\/<\/a>)<\/li>\r\n<li>2009 &#8211; 2011. Partecipazione al IEA-ECES Annex 21 sul Thermal Response Test<\/li>\r\n<li>2009 &#8211; 2012. Partecipazione al Geothermal Panel<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Pubblicazioni<\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Focaccia, Tinti, Barbaresi (2018) &#8220;Simulation of Observed Temperature Field below a Building&#8221;\u00a0Environmental Geotechnics, p. 1-39, doi: 10.1680\/jenge.17.00105<\/li>\r\n<li>Cazorla-Mar\u00edn, Montagud, Corber\u00e1n, Tinti, Focaccia (2018) &#8220;Upgrade of the B2G dynamic geothermal heat exchanger model: Optimal location of the ground nodes&#8221;\u00a0IGSHPA Conference and Expo, vol. 48<\/li>\r\n<li>Focaccia, Tinti, Monti, Amidei, Bruno (2016) &#8220;Shallow geothermal energy for industrial applications: A case study&#8221;\u00a0Sustainable Energy Technologies and Assessments, p. 93-105,\u00a0doi: 10.1016\/j.seta.2016.05.003<\/li>\r\n<li>Al-Khoury, Focaccia (2016) &#8220;A spectral model for transient heat flow in a double U-tube geothermal heat pump system&#8221;, Renewable Energy, vol. 85, p.195-205,\u00a0doi:10.1016\/j.renene.2015.06.031<\/li>\r\n<li>Bruno, Tinti, Focaccia (2015) &#8220;Estimating Thermal Response Test Coefficients: Choosing Coordinate Space of The Random Function&#8221;, Mathematical Geoscience, p. 1-21,\u00a0DOI\u00a010.1007\/s11004-015-9612-z<\/li>\r\n<\/ul>\r\n\r\n\r\n<div class=\"owc-section-page \" data-up=\"&#9658;\" data-down=\"&#9660;\"><div class=\"owc-sp-open \"><h2><span class=\"owc-sp-toggle-arrow\">&#9658;<\/span> Altre pubblicazioni<\/h2><\/div><div class=\"owc-sp-content \">\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li>Tinti, Focaccia, Bruno (2015) &#8220;Thermal response test for shallow geothermal applications: a probabilistic analysis approach&#8221;, Geothermal Energy, vol.3, issue 6,\u00a0doi:10.1186\/s40517-015-0025-5<\/li>\r\n<li>Focaccia (2013) \u201cThermal response test numerical modeling by using a dynamic simulator\u201d, Geothermal Energy, vol. 1, p. 3-14, ISSN: 2195-9706<\/li>\r\n<li>Focaccia, Tinti (2013) \u201cAn innovative Borehole Heat Exchanger configuration with improved heat transfer\u201d, Geothermics, vol. 48, p. 93-100, ISSN: 0375-6505<\/li>\r\n<li>Focaccia, Bruno, Tinti (2013) \u201cA software tool for Geostatistical Analysis of Thermal Response Test data: GA-TRT\u201d, Computer and Geoscience, vol. 59, p. 163-170, ISSN: 0098-3004<\/li>\r\n<li>Giambastiani, Tinti, Mendrinos, Mastrocicco (2014) \u201cEnergy performance strategies for the large scale introduction of geothermal energy in residential and industrial buildings: The GEO.POWER project\u201d, Energy Policy, Volume 65, February 2014, Pages 315-322 M.<\/li>\r\n<\/ul>\r\n\r\n\r\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Progettazione di impianti geotermici Per dimensionare correttamente un grande impianto di climatizzazione e riscaldamento geotermico \u00e8 necessario analizzare le interazioni tra i vari geoscambiatori, per garantire il funzionamento del sistema\u00a0nel tempo.Il servizio di progettazione di grandi impianti geotermici soddisfa tutti i casi in cui\u00a0 gli approcci e le metodologie standard non possono essere applicati. E&#8217; [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":988,"menu_order":4,"comment_status":"open","ping_status":"open","template":"","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":"","_links_to":"","_links_to_target":""},"class_list":["post-1015","page","type-page","status-publish","hentry"],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.serengeo.com\/it\/wp-json\/wp\/v2\/pages\/1015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.serengeo.com\/it\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.serengeo.com\/it\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.serengeo.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.serengeo.com\/it\/wp-json\/wp\/v2\/comments?post=1015"}],"version-history":[{"count":0,"href":"https:\/\/www.serengeo.com\/it\/wp-json\/wp\/v2\/pages\/1015\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.serengeo.com\/it\/wp-json\/wp\/v2\/pages\/988"}],"wp:attachment":[{"href":"https:\/\/www.serengeo.com\/it\/wp-json\/wp\/v2\/media?parent=1015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}